Hiroxis. Built to Fit. Ready to Perform.
Dental Equipment

Hiroxis. Built to Fit. Ready to Perform.

YOFO Medical Technology Co., Ltd · China

Precio
Precio bajo consulta
Ubicación del proveedor
A1 Building, National Health Big Data Industrial Park, Intersection of Xiyou Road and Kongquetai Road, High-tech Zone, Hefei, Anhui, China

Descripción del producto

Designed to bring advanced imaging performance to practices of any size, Hiroxis pairs the world’s smallest CBCT footprint with a field of view of up to 16 × 15 cm and simultaneous multiple-view imaging without image stitching, powered by the world’s first helical dental CBCT technology. Ready straight out of the box, Hiroxis requires no installation and no calibration. Its shoulder rests enhance patient stability, helping reduce motion and improve scan consistency. World’s Smallest. Ready Out of the Box Advanced Imaging Beyond Its Size Designed Around Patients and Practices Built to Last. Designed for Value Product Information & Safety Instructions Ultra-compact footprint: 0.66 m² Simply unpack, connect and start scanning. Powered by the world’s first helical dental CBCT technology, Hiroxis delivers broad anatomical coverage from an exceptionally compact system. Acquire CT, digital panoramic, 3D frontal and lateral views and 3D TMJ views simultaneously from a single rotation scan. FOV options: 16 × 15 cm / 16 × 9 cm / 8 × 8 cm / 4 × 4 cm Fine anatomical structures with high clarity. Large-FOV CT images are reconstructed in just 2.6 seconds. Fine anatomical structures are clearly visualized. Acquire CT, digital panoramic, 3D frontal and lateral views and 3D TMJ views simultaneously from a single rotation scan. Improve workflow efficiency, reduce unnecessary repeat examinations and minimize patient radiation exposure. Stable positioning helps children, older patients and other patients remain still during scanning, reducing repeat scans and unnecessary radiation exposure. Faster positioning streamlines operator workflow and improves overall clinical efficiency. Consistent patient positioning delivers more reliable image quality across operators. Improved patient stability helps reduce motion artifacts, minimizing repeat scans and unnecessary radiation exposure. The compact footprint supports flexible room planning, making Hiroxis ideal for practices where space matters. Engineered for up to 12 years of reliable operation, Hiroxis delivers exceptional durability and a lower total cost of ownership through two key engineering innovations. Low operating current and short pulsed exposures help maximize X-ray tube life for reliable long-term performance. 4–8 mA typical operating current for high-quality imaging with reduced tube wear. ≤20 s pulsed exposure minimizes operating time and extends tube life. An integrated structure and slip-ring technology help maximize system durability for reliable long-term performance. A one-piece integrated design reduces movement between components for stable imaging performance. Slip-ring data transmission minimizes mechanical wear for greater reliability and longer service life. Moving beyond conventional CBCT aesthetics, Hiroxis features a distinctive industrial design that stands out in any clinical environment. Customizable color options provide greater flexibility for different practice settings. Dental Cone Beam Computed Tomography System The Dental Cone Beam Computed Tomography System is intended to be used by medical institutions for X-ray image diagnosis on oral and maxillofacial areas through X-ray Cone Beam Computed Tomography (CBCT).This product is reusable. Radiologists or technologists with a background in medical imaging in medical institutions The system is not recommended for pregnant women or women who may become pregnant. *For prohibited contents or precautions, please refer to the instructions. Please read the product instructions carefully or purchase and use under the guidance of medical professionals. This system is required to generate X-ray radiation during use to achieve its intended use, while the X-ray radiation may be dangerous. Operators are strongly urged to follow the radiation protection procedures and the relevant requirements of user manual, otherwise the useful and scattered beams can cause harm to patients and operators! The operators and maintenance personnel of this system should be properly trained. The Company believes that all authorized operators and maintenance personnel of this system should understand and have adequate training and knowledge on the dangers of X-rays. The Company is not responsible for any injuries or damages caused by X-ray radiation. When the system is on, the components carry dangerous voltages, and if there is any improper use and maintenance, it may cause electric shock hazards. To avoid the risk of electric shock, it is strictly forbidden to disassemble the protective enclosure of the components when the equipment is powered on, nor to turn on the device after removing the protective enclosure of the components; It is strictly forbidden to clean the components when the system is powered on. To avoid the risk of electric shock and affecting the basic performance of the system, do not use a damp cloth to clean the inside parts of the equipment, and prevent from liquid entry inside when cleaning the surface of the equipment. To avoid the risk of electric shock, this equipment must only be connected to a supply mains with protective earth. Small Footprint, Exceptional Performance. Leave the Expertise to Us

Especificaciones

Este producto aún no tiene una ficha de especificaciones publicada. Consulte directamente al proveedor.

Imágenes del producto

Hiroxis. Built to Fit. Ready to Perform.
Hiroxis. Built to Fit. Ready to Perform.
Hiroxis. Built to Fit. Ready to Perform.

Más productos de este proveedor

Productos relacionados